Classification of biological safety cabinets:
According to the NSF49 standard, the medium of biosafety level 1
(P1) refers to ordinary harmless bacteria, viruses and other
microorganisms; the medium of biosafety level 2 (P2) refers to
general pathogenic bacteria, viruses and other microorganisms;
biosafety The medium of level 3 (P3) refers to microorganisms such
as potent/fatal bacteria and viruses, but can be cured after
infection; the medium of biosafety level 4 (P4) refers to
microorganisms such as potent/fatal bacteria, viruses, etc., which
are not easy to cure after infection . This standard divides the
biological safety cabinets into grades I, II, and III, which can be
applied to the operation of media of different biological safety
levels.
Low Noise Leakproof ULPA Class10 Biosafety Cabinet Level 2 BSC
Biosafety Cabinet is a biosafety level 2 (P2) biosafety cabinet
Model | BSC-1000B2 |
Clean Grade | HEPA:ISO 5 calss ( Class100 ) |
ULPA:ISO 4 Class ( Class10 ) | |
HEPA Filter | HEPA:≥99.995% , @0.3μm |
ULPA:≥99.999% , @0.12μm | |
Air tightness | 99.99≤E≤99.999 |
Overall Dimensions | 1200×800×2120 mm |
Working Space | 1000×700×600mm |
Downflow Velocity | 0.35m/s |
Forward intake wind speed | 0.25m/s±0.025m/s |
Low Noise Leakproof ULPA Class10 Biosafety Cabinet Level 2 BSC
Biosafety Cabinet Precautions:
1. In order to avoid cross-contamination between items, the items
needed during the entire work process should be lined up and placed
in the Low Noise Leakproof ULPA Class10 Biosafety Cabinet Level 2
BSC Biosafety Cabinet before the work starts, so that there is
nothing before the work is completed Items need to be taken out or
put in through the air flow compartment. Special attention: no
items can be placed on the front and rear return grills to prevent
the return grills from being blocked and affecting the air
circulation.
2. Before starting work and after finishing the work, the air flow
should be maintained for a period of time to complete the
self-cleaning process of Low Noise Leakproof ULPA Class10 Biosafety
Cabinet Level 2 BSC Biosafety Cabinet. The cabinet should be
cleaned and disinfected after each test.
3. During operation, try to minimize the number of in and out of
both arms. When entering and exiting the Low Noise Leakproof ULPA
Class10 Biosafety Cabinet Level 2 BSC Biosafety Cabinet, the
movements should be slow to avoid affecting the normal airflow
balance.
4. The movement of items in the cabinet should follow the principle
of moving from low pollution to high pollution, and the experiment
operation in the cabinet should be carried out from the clean area
to the polluted area. Before operation, a towel soaked with
disinfectant can be used as a bottom to absorb any droplets that
may spill.
5. Try to avoid placing centrifuges, oscillators and other
instruments in the Low Noise Leakproof ULPA Class10 Biosafety
Cabinet Level 2 BSC Biosafety Cabinet, so as to prevent the
particulate matter on the filter membrane from shaking off when the
instrument is shaken, causing the cleanliness of the cabinet to
decrease; at the same time, these The airflow of the instrument's
heat dissipation vent may affect the airflow balance in the
cabinet.
6. Low Noise Leakproof ULPA Class10 Biosafety Cabinet Level 2 Open
flames cannot be used in the BSC Biosafety Cabinet to prevent the
high temperature and fine particles generated during the combustion
process from entering the filter membrane and damaging the filter
membrane
![]() |