Large Capacity Refrigerated Centrifuge Features:
1. LCD display, microprocessor control, large capacity refrigerated
centrifuge can display the set parameters and actual parameters at
the same time.
2. AV motor: high torque and variable frequency, free from carbon
dust pollution.
3. Imported drive system and automatic control system ensure stable
and reliable operation.
4. Safety: overheating and overspeed protection, electronic
locking, unbalance detection.
5. Multiple programs can be set, and parameters can be modified
during operation.
6. Multi-level acceleration and deceleration control.
Max RCF | 58696×g |
Max Speed | 25000r/min |
Max Capacity | 4×1000mL |
Timer Range | 1min-99h59min, with continuous run function |
Temp control range | -20℃~+40℃ |
Noise level | ≤65dB(A) |
Power supply | AC220V 50Hz |
Large Capacity Refrigerated Centrifuge instructions:
1. the host should be placed without heat source, the source, no
electromagnetic interference, "ventilation, no direct sunlight"
flat solid work surface or ground;
2. connect the power supply, pay attention to the power supply
voltage and capacity;
3. open the host cover, tighten the rotor to the drive shaft,
completes the balance samples (sample equivalent axisymmetric
placed), cover door cover;Number
4. select the correct rotor, set speed (RCF), speed, temperature,
the separation of time;
5. press the start key to start the;
6. arrived at the set time, the instrument automatically stop; The
door cover, take out separate good sample, centrifugal is complete;
7. centrifugal, after the completion of the chamber and the engine
clean, and to turn it off.
Large Capacity Refrigerated Centrifuge Use Notice:
1. pay attention to use correct rotor, no speeding operation.
2. completes the sample amount of axisymmetric placed in the rotor,
run rotor balanceOperating this product by the laboratory
professionals, not used to treat, scope of application, taboos,
adverse reactions, no risk to the public.
Large Capacity Refrigerated Centrifuge Note:
1. not in damp, high temperature and dust use centrifuge;
2. please make sure that before starting the equipment level, to
receive strength evenly in the four corners, balancing centrifugal
samples is good, be sure to with an even symmetry in the centrifuge
tube. If big shake appeared in the process of operation, please
stop the machine immediately to check;
3. In order to ensure safety, be sure to check before starting the
rotor, it is forbidden to overspeed centrifugal;
4. In the process of operation, it is forbidden to move the
centrifuge, prohibit open;
5. After the separation, please timely lumen from the centrifuge
will be clean and prevent rust. If long time no centrifuge, need to
remove the rotor, wipe clean place. Set aside. Time is too long can
lead to the rotor and the motor shaft rust, remove difficulties;
6. Often should rotor of centrifuge, the centrifugal tube, adapter,
such as inspection, have crack, aging phenomenon is found, please
change in time.